aoyue INT 2702A+ Instruction Manual page 16

Lead-free repairing system
Hide thumbs Also See for INT 2702A+:
Table of Contents

Advertisement

6.
Adjust the temperature compensation using the UP and
DOWN buttons of the Soldering iron adjustment buttons.
A zero "0" on the first digit signifies addition to the current
7.
temperature and a minus "-" on the first digit will subtract
the displayed value from the current settings.
Confirm the change by pressing the air pressure down
8.
button.
Initial display
when in cali-
bration mode
Solder Iron Digital Temperature Calibration Example
The external temperature sensor displays 248 to 252 degrees.
The set temperature and displayed actual temperature of the
soldering iron is 300 degrees.
300 — 248 = 52. An additional adjustment of 52 degrees is
required.
Enter calibration mode
We increase from "0000" to "0052".
Exit calibration mode.
The external temperature sensor would now display 298 to
302 degrees.
16
DIGITAL CALIBRATION
Increase tem-
perature by 38
degrees
Decrease tem-
perature by 30
degrees

Hide quick links: