aoyue INT 2702A+ Instruction Manual page 11

Lead-free repairing system
Hide thumbs Also See for INT 2702A+:
Table of Contents

Advertisement

NOTES:
1. Hot Air Gun Temperature is adjustable between 100°
and 480°C with an increment of 2° on each step.
2. Hot Air Gun Airflow Rate is adjustable between 10
and 100 with an increment of 2 on each step.
C. SOLDERING IRON
1. Connect the Soldering Iron connection assembly to the 6-pin
receptacle located at the front of the control panel ("7" from the
CONTROL PANEL GUIDE).
2. Follow the initial procedures ("A. INITIAL PROCEDURES").
3. Connect the vacuum tube to the Smoke Absorber Terminal or
Vacuum Cap ("6" from the control panel). If smoke absorber
function is to be used.
4. Activate the "SOLDER IRON" Activation switch ("9" from control
panel). This will automatically start to increase the temperature of
the soldering iron to 350°C (default).
5. Adjust the soldering iron temperature using the SOLDER/DESOLDER
TEMPERATURE ADJUSTMENT buttons ("4" from the control panel).
6. If smoke absorber function is to be used. Activate the "SMOKE
ABSORBER" Activation switch ("11" from the control panel).
7. Start using the soldering iron as soon as desired temperature is
reached.
8. When the task is finished, deactivate the SMOKE ABSORBER switch.
9. Deactivate the SOLDER IRON activation switch.
10. Allow sufficient time for the soldering iron to cool down before
keeping in a safe storage.
D. DESOLDERING GUN
1. Connect the De-soldering gun connection assembly to the 6-pin
receptacle located at the front of the control panel ("7" from the
CONTROL PANEL GUIDE).
2. Follow the initial procedures ("A. INITIAL PROCEDURES").
OPERATING GUIDELINES