2.2.5.2
Connection procedure
(1) Connects the transceiver to the computer using the inter-
face cable (KPG-36U/36X).
Note:
You must install the KPG-36U/36X driver in the comput-
er to use the USB programming interface cable (KPG-
36U/36X).
(2) When the POWER switch on, user mode can be entered
immediately. When PC sends command the transceiver
enter PC mode, and "PROGRAM" is displayed on the LCD.
When data transmitting from the transceiver, the red LED
lights.
When data receiving to the transceiver, the green LED
light.
Note:
The data stored in the computer must match the "Model
Name" when it is written into the flash memory.
2.2.5.3
KPG-36U/36X description (USB programming in-
terface cable: Option)
The KPG-36U/36X is a cable which connects to a USB port on a
computer.
When using the KPG-36U/36X, install the supplied CD (with driv-
er software) in the computer. The KPG-36U driver runs under
Windows XP, Vista, 7, 8 or 8.1.
The KPG-36X driver runs under Windows Vista, 7, 8 or 8.1.
The latest version of the USB driver is available for download
from the following URL:
http://www.kenwood.com/usb-com/
(This URL may change without notice.)
2.2.5.4
Programming software KPG-D1/D1N (Ver. 1.60 or
later) description
The FPU is the programming software for the transceiver sup-
plied on a CD-ROM. This software runs under Windows Vista 7,
8 or 8.1 on a PC.
The data can be input to or read from the transceiver and edited
on the screen.
Note:
KPG-D1N can't be used for E, E2 types.
2.2.6 Firmware Programming Mode
2.2.6.1
Preface
Flash memory is mounted on the transceiver. This allows the
transceiver to be upgrade when new features are released in the
future. (For details on how to obtain the firmware, contact Cus-
tomer Service.)
2.2.6.2
Connection procedure
Connect the transceiver to the personal computer using the pro-
gramming interface (KPG-36U/36X). (Connection is same as in
the PC mode.)
2.2.6.3
Programming
(1) Start up the firmware programming software (KENWOOD
Firmware Loader). The KFL.exe exists in the KPG-D1/D1N
installed holder.
(2) Set the baud rate to "auto" or 1152000, 576000, 115200,
and 57600.
(3) Set the firmware to be upgrade by file name item.
(4) Enter the Firmware programming mode by using section
"2.2.2 How to Enter Each Mode". Then, the yellow LED on
the transceiver light and "FIRMWARE PROG" is displayed.
(5) Check the connection between the transceiver and the per-
sonal computer, and make sure that the transceiver is in
the Program mode.
(6) Press "Write" button in the window. When the transceiver
starts to receive data, the "LOADING" display lights.
(7) If writing ends successfully, the checksum is calculated
and a result is displayed.
(8) If you want to continue programming other transceivers, re-
peat step (4) to (7).
Note:
If write is perfomed by KFL, Firmware programming
mode will start automatically even if Firmware program-
ming is set to disable in the programming software.
2.2.6.4
Function
If you press the [
] key while "FIRMWARE PROG" is dis-
played, the checksum is calculated, and a result is displayed. If
you press the [
] key again while checksum is displayed,
"FIRMWARE PROG" is redisplayed.
2.2.7 Clone Mode
Programming data can be transferred from one transceiver to an-
other by connecting them via their external universal connectors.
The operation is as follows.
The following data cannot be cloned.
• Tuning data
• Embedded message with password
• ESN (Electronic Serial Number) data
Key guide on the Clone/ Front Panel Programming Pass-
word input screen.
• Confirm ([
] key): The password confirmation
• Delete ([
] key): Delete the latest digit from the current
password number (Press and hold to delete all password
numbers)
• Select([
] key): Determine the latest digit of the password
number.
(1) In the source transceiver, enter the clone mode by using
section "2.2.2 How to Enter Each Mode". When the Clone/
Front Panel Programming Password is set to the transceiv-
er, "Input Password" is displayed on the LCD.
If the password is not set, the transceiver displays "CLONE
MODE".
(2) When you enter the correct password, "CLONE MODE" is
displayed, the transceiver can be used as the cloning
source. The following describes how to enter the pass-
word.
(3)
- How to enter the password using the keypad;
If one of the keys 0 to 9 is pressed while the "Input Pass-
word" is displayed, the password number is displayed on
the LCD.
Each press of the key shifts the display in order to the
left.
When you enter the password and press [
"CLONE MODE" displayed if the entered password is
correct. If password is incorrect, "Input Password" is re-
displayed.
- How to enter password using the [] and [] keys;
If the [] / [] key is pressed while "Input Password" is
displayed, the Clone/ Front Panel Programming Pass-
word input screen is displayed.
If the [] or [] key is pressed while the clone/ Front
Panel Programming Password input screen is displayed,
the number (0 to 9) blinks on the LCD. When you press
the [
] key, currently selected number is determined. If
you press the [
] key after entering password in this
procedure, "CLONE MODE" is displayed if entered pass-
] or [*] key,
(No.RA015<Rev.002>)1-7

Hide quick links:

Advertisement

loading