Download Print this page

Kenwood NX-5300 Service Manual page 65

Uhf digital transceiver
Hide thumbs Also See for NX-5300:

Advertisement

Item
Condition
Panel tuning mode
[P25
1) Adj item:
(LSM)]
[P1 SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 1kHz/
±3.3kHz)
[NXDN
1) Adj item:
Narrow]
[Nn SQL]
Adjust:[***]
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-1dB
(MOD: 400Hz/
±2.5kHz)
[NXDN
1) Adj item:
Very
[Nv SQL]
Narrow]
Adjust:[***]
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 400Hz/
±1.2kHz)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
SSG
[Open Squelch (P25
Distor-
LSM)]
tion
2) Adj item:
meter
[Low1]→
Oscillo-
[Low5]→
scope
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 1kHz/
±3.3kHz)
1) Adj item:
SSG
[Open Squelch
Distor-
(NXDN Narrow)]
tion
2) Adj item:
meter
[Low1]→
Oscillo-
[Low5]→
scope
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -1dB
(MOD: 400Hz/
±2.5kHz)
1) Adj item:
SSG
[Open Squelch
Distor-
(NXDN Very Nar-
tion
row)]
meter
2) Adj item:
Oscillo-
[Low1]→
scope
[Low5]→
[Center3]→
[High2]→
[High6]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 400Hz/
±1.2kHz)
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel
Uni-
versal
con-
nector
Panel ANT
Panel
Uni-
versal
con-
nector
Panel ANT
Panel
Uni-
versal
con-
nector
Adjustment
Method
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
[Panel tuning mode]
After input signal from
SSG, press [
] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
(No.RA015<Rev.002>)1-65
Specifi-
cations
/Remarks

Hide quick links:

Advertisement

loading