Advertisement

Item
Condition
Panel tuning
mode
9. P25
1) Adj item:
H-CPM
[P2 P2DEV]
Devia-
Adjust:[****]
tion
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
*F5,F6,K5,K6
type only: Press
and hold the
[Right] key to en-
ter [Center1]
(Over Lap
High)→
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
10.
1) Adj item:
NXDN
[Nn NDEV]
High
Adjust:[****]
Devia-
Deviation meter
tion
LPF: 3kHz
[NXDN
HPF: OFF
Narrow]
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
*F5,F6,K5,K6
type only: Press
and hold the
[Right] key to en-
ter [Center1]
(Over Lap
High)→
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Devia-
[P25 H-CPM Devia-
tion
tion]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
*F5,F6,K5,K6 type
only: [Center1]
(Over Lap High)→
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[NXDN High Devia-
tion
tion (NXDN Narrow]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
*F5,F6,K5,K6 type
only: [Center1]
(Over Lap High)→
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Adjustment
Method
Write fixed value "498"
3090~3215Hz
(F2,F3,K2,K3),"497"
(F5,F6,K5,K6) for each
[PC test
adjustment point. Trans-
mode]
mit at each adjustment
Press [Apply
point and check that the
All] button to
deviation is between
store the
3090Hz and 3215Hz.
adjustment
Deviation meter
value after all
LPF: 3kHz
adjustment
HPF: OFF
points have
been adjust-
[Panel tuning mode]
ed.
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write fixed value "497"
2995~3117Hz
for each adjustment
point. Transmit at each
[PC test
adjustment point and
mode]
check that the deviation
Press [Apply
is between 2995Hz and
All] button to
3117Hz.
store the
Deviation meter
adjustment
LPF: 3kHz
value after all
HPF: OFF
adjustment
points have
[Panel tuning mode]
been adjust-
PTT: ON
ed.
[PC test mode]
PTT: Press [Transmit]
button
(No.RA015<Rev.002>)1-51
Specifica-
tions
/Remarks