2.8 Installation location

The MTH is to be installed, according to choice, as an over-sink or under-sink unit
in a closed, frost-free room in the vicinity of the water tap (dismantled unit is to be stored
in a frost-free place, as residual water always remains in the unit).
2.9 Unit installation
Under-sink installation with AHu 40 MTH or AHEu 40 MTH fitting
Loosen cover securing screws by two turns.
Using a screwdriver, release the snap closing catch.
Take off the unit front cover with heating block.
With the help of a pair of nippers, break out the feed-through opening for the connection cable
(break-off point).
Fix the unit rear panel to the wall using dowels and screws; use the unit rear panel as a drilling
template.
Installation, last in – first out.
Screw connecting hoses of the AHu 40 MTH or AHEu 40 MTH unit onto the water connections (1 and 2)
(see fittings description), when doing this use a 14 mm spanner on the unit as a counter-force.
Over-sink installation with AHo 40 MTH fitting
The cold water pipe and AHo 40 MTH wall fitting must be safely secured.
1. Screw the AHo 40 MTH wall fitting into the wall disc.
2. Screw the MTH unit onto the fitting; when doing this use a 14 mm spanner on the unit as a
counter-force.
Over-sink installation without wall fitting
Installation of the unit as shown in illustration

2.10 Electrical connection

The unit must be connected to the protective earth terminal.
• This appliance is fitted with a power supply cabel.
For the qualified installer
Areas of application for different water analysis
reference temperatures* designation
Standard
at
at 15 °C
20 °C
Ωcm
≥ 1970 Ωcm
1100,9
≤ 1190.9 mS/m
≤ 1103 mS/m
µS/cm
≤ 1030 µS/cm
1909,9
(Gerät um 180 ° gedreht).
at
25 °C
≥ 1900 Ωcm
≤ 1111 mS/m
≤ 1110 µS/cm
,