Regulations And Provisions - AEG MTH 350 Operating And Installation Instructions

Hydraulically controlled, open small-instantaneous water heater with bare-wire heating system
Table of Contents

Advertisement

For the qualified installer

2.6 Regulations and provisions

• Installation (water and electrical installation), as well as the first start-up and maintenance of this
unit, may only be carried out by a qualified installer in accordance with these instructions.
• Faultless operation and operational safety are only guaranteed if the original accessories and spare
parts intended for the unit are used.
• In accordance with IEE and WRC Regulations.
• Regulations of the local energy supply company.
• Regulations of the relevant water supply company.
The following should also be observed:
• The unit rating plate.
• Technical data (see Table 1).
The specific electrical resistance of the water must not be lower than specified on the rating
plate. In the case of a water grid supply network, the lowest electrical resistance of the water is
to be taken into account (see Table 2). Your water supply company will advise you of the
specific electrical resistance or the electrical conductivity of the water.
Water installation:
• A safety valve is not necessary.
• Operating the unit with preheated water is not permitted!
• Fittings for pressurised units are not permitted!
Electrical installation:
• It must be possible to isolate the unit from the main supply on all poles with an isolating distance of
at least 3 mm, for example using fuses.
2.7 Technical data
Type
Rated power
Rated voltage
Rated current
Hot water output ∆ϑ = 25 K
Flow rate „on"
Flow rate „off"
Automatic flow regulation
Pressure drop (during switch-on flow)
Max. inlet temperature
Rated capacity
Design
Weight
Protection class in accordance with EN 60335
Protection mode in accordance with EN 60529 IP 25
Test mark
Structural inspection test certificate
Water connections (external thread)
Electrical connection
Heating system
Area of use
Range of use with regard to specific
electrical resistance / conductivity
Table 1
14
(the data on the unit identification plate are applicable)
MTH 350
3.5 kW
230 V ~
15 A
2.0 l/min
≤ 2.0 l/min
≥ 0.9 l/min
2.2 l/min
0.05 MPa
25 °C
0.1 l
open
1.4 kg
1
See unit identification plate
PA-No. (Nr. for Germany)
G 3/8, surface installation
1/N/PE ~ 230 V
Bare-wire
Low-lime and limy water
See Table 2