11 Specifications

11
Specifications
Items
Model
SI-N3
• Group 2 Server (UCMM capable).
• Explicit Messages: Fragmentation is supported. Up to 32 bytes can be input and output.
• Polled I/O Messages: Fragmentation is not supported. Up to 8 bytes can be input and output.
SI-N3 Supported
Messages
• Faulted Node Recovery / Offline Connection Set Messages / Automatic Device Replacement
(ADR).
• Change of State Message (COS). COS can be used as an I/O Input Assembly.
Input: 20 types (4 to 8 bytes)
I/O Assembly
Instance
Output: 20 types (4 to 8 bytes)
DeviceNet
Conformance Level 27: Passed
Specification
DeviceNet
AC Drive
Profile
Voltage: 11 to 25 Vdc
Input Power
Current: 40 mA
Connector Type 5-pin open-style screw connector
Isolated Physical Layer
Physical Layer
Type
CAN transceiver + photocoupler
Programmable from drive keypad or network:
MAC ID Setting
MAC ID 0 to 63
Programmable from drive keypad or network:
• 125/250/500 kbps
Communication
s Speed/Baud
• Auto Baud Rate
Rate
• Idle Mode Detect
• Heartbeat
Ambient
-10 °C to +50 °C (14 °F to 122 °F)
Temperature
Humidity
95% RH or lower with no condensation
Storage
-20 °C to +60 °C (-4 °F to 140 °F) allowed for short-term transport of the product
Temperature
Indoors and free from:
• Oil mist, corrosive gas, flammable gas, and dust
• Radioactive materials or flammable materials, including wood
Area of Use
• Harmful gas or fluids
• Salt
• Direct sunlight
• Falling foreign objects
Altitude
1000 m (3280 ft) or lower