4 Option Components

4
Option Components
u
DeviceNet Option
Figure 2
F
E
A – Connector (CN5)
B – Installation hole
C – LED (MS)
D – LED (NS)
<1>
Refer to Option LED Display on page 13
<2> Connect the provided ground wire during installation. Installation on GA700 and GA800 drives does not require
the ground wire.
u
Terminal Block CN1
The communication terminal is a pluggable terminal block that serves as the connection
point of the DeviceNet network communication cable to the option.
Terminal
Pin
1
2
3
4
5
12
G
SI-N3
<2>
<1>
for details on the LEDs.
Figure 2 DeviceNet Option Components
Table 2 Terminal Descriptions
Color
Signal
Black
Blue
CAN_L
Shield
White
CAN_H
Red
YASKAWA ELECTRIC TOBP C730600 84D YASKAWA AC Drive Option SI-N3 Installation Manual
B
C
D
E – Ground terminal (FE) and installation
hole
<2>
F – Terminal block CN1
G – Option model number
V-
Network common
CAN data Low
Cable shield
CAN data High
V+
Communications network power DC +24V
A