Error Log Codes - Frymaster FQE60U FilterQuick easyTouch Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

PROBLEM
A. Incorrect setup procedure.
B. Another function is in process.
Top off reservoir
C. Dispose valve not completely
won't fill.
D. Bulk oil tank is empty.
E. Solenoid, pump or switch issue.
Top off reservoir
A. Pump or line issues beyond the
or vat filling
slow.
6.2.7

Error Log Codes

See section 1.12.2.1 in the FQ4000 controller manual for instructions to access the Error Log.
Code
E13
TEMPERATURE PROBE FAILURE
E16
HIGH LIMIT 1 EXCEEDED
E17
HIGH LIMIT 2 EXCEEDED
E18
HIGH LIMIT PROBLEM
DISCONNECT POWER
E19
HEATING FAILURE – XXX F or XXX C
E25
HEATING FAILURE - BLOWER
E27
HEATING FAILURE - PRESSURE SWITCH - CALL
SERVICE
E28
HEATING FAILURE – XXX F or XXX C
E29
TOP OFF PROBE FAILURE - CALL SERVICE
E32
DRAIN VALVE NOT OPEN - FILTRATION AND TOP
OFF DISABLED - CALL SERVICE
E33
DRAIN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E34
RETURN VALVE NOT OPEN - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E35
RETURN VALVE NOT CLOSED - FILTRATION AND
TOP OFF DISABLED - CALL SERVICE
E36
VALVE INTERFACE BOARD FAILURE - FILTRATION
AND TOP OFF DISABLED - CALL SERVICE
E37
AUTOMATIC INTERMITTENT FILTRATION PROBE
FAILURE - FILTRATION DISABLED - CALL SERVICE
PROBABLE CAUSES
closed.
scope of operator troubleshooting.
ERROR MESSAGE
CORRECTIVE ACTION
A. Power cycle fryer by disconnecting and
reconnecting 5-pin bulk oil control
power cord on rear of fryer.
B. If a filtration or any other filter menu
function is in process or FILTER NOW?
YES/NO, CONFIRM YES/NO, or SKIM
VAT are displayed, wait until the
process is complete and try again.
C. Ensure the dispose valve handle is
pushed fully closed.
D. Call your bulk oil provider.
E.
Call you FAS for assistance.
A. Contact your bulk oil provider.
TEMP Probe reading out of range
High limit temperature is past more than
410°F (210°C), or in CE countries, 395°F
(202°C)
High limit switch has opened.
Vat temperature exceeds 460°F (238°C) and
the high limit has failed to open. Immediately
disconnect power to the fryer and call service.
Heating Control latch circuit failed.
Heat Contactor failed to latch.
The air pressure switch(s) failed to close.
The air pressure switch has failed closed.
The fryer has failed to ignite and has locked
out the ignition module.
ATO RTD reading out of range
Drain
valve
confirmation is missing
Drain
valve
confirmation is missing
Return valve
confirmation is missing
Return
valve
confirmation is missing
Valve Interface Board connections lost or
board failure.
AIF RTD reading out of range.