Troubleshooting; Controller And Heating Problems - Frymaster FQE60U FilterQuick easyTouch Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

6.2

Troubleshooting

6.2.1

Controller and Heating Problems

Problem
No display on the
controller.
FQ4000 displays
IS VAT FULL? YES
NO after a
filtration.
FQ4000 displays IS
DRAIN CLEAR?
FQ4000 displays
CHANGE FILTER PAD?
Fryer does not heat.
Fryer heats until
high-limit trips with
heat indicator ON.
Fryer heats until
high-limit trips
without heat
indicator ON.
FQ4000 displays
MISCONFIGURED
ENERGY TYPE
FQ4000 displays VAT
ID CONNECTOR NOT
CONNECTED
Controller locks up.
Probable Causes
A. No power to fryer.
B. Failed controller or another
component
A. Normal operation during most at
the beginning or end of most
filtration functions.
B. If the display appears many times
during a filter it could be an
indication of slow oil return.
Drain is clogged, and oil failed to drain.
Filter error has occurred, filter pad
clogged, 25-hour filter pad change
prompt has occurred or change filter
pad was ignored on a prior prompt.
A. Power cord(s) not plugged in.
B. Controller or other components
have failed.
Temperature probe or controller has
failed.
Contactor or controller has failed
Energy type in fryer setup is incorrect.
Controller
locator
disconnected.
Controller error.
A. Verify that the fryer is plugged in
and that the circuit breaker is not
tripped.
B. Call your FAS for assistance.
A. Ensure the vat is full of oil and
press the √ button.
B. See section 5.3 troubleshooting –
Filter Pump runs, but oil return is
very slow.
Clear drain with Fryers Friend and
press √ button.
resume.
Change the filter pad and ensure
the filter pan has been removed
from the fryer for a minimum of 30
seconds. Do NOT ignore CHANGE
FILTER PAD prompts.
A. Verify that all the power cord(s)
are
receptacle(s), locked into place
and that circuit breaker is not
tripped
B. Call your FAS for assistance.
Call your FAS for assistance.
Call your FAS for assistance.
Ensure that the fryer is configured
properly for the correct energy type.
Ensure the 6-pin locator is connected
missing
or
to rear of controller and it properly
grounded in control box.
Remove and restore power to the
controller.
your FAS for assistance.
6-2
Corrective Action
Filtration will
fully
seated
in
If problem persists, call
their