System Operating Information; Information Settings - Culligan G1 Series Installation, Operation And Service Instructions

Reverse osmosis water treatment systems
Table of Contents

Advertisement

System Operating Information

At any time, you can view the system operation information. The information includes settings and performance data.
>1)GO TO RUNNING
2)GO TO OFFLINE
3)INFORMATION
4)SETUP

Information Settings

NOTE
When you display any Information screen, it will stay on the display until changed by the operator.
Screen Display
FFLOW 0.00 PGM
DFLOW 0.00 GPM
PFLOW 0.00 GPM
RECOVERY 0.0 %
TDS PPM
TDS IN
= 1075
TDS OUT = 192
% REJ
= 82
TDS AVERAGE
0
PPM
RECOVERY 0.0%
PFLOW 0.00 GPM
TDS OUT = 169
ACTUAL NFLOW:
0.00
GPM
P IN
122 PSI
P OUT 124 PSI
dP
-2 PSI
Actual Temp:
91 F
PS1 = OPEN
PTLO = OPEN
FS HI = OPEN
FS LO = OPEN
Culligan® Series G1 Reverse Osmosis
60
1.
Press
to select 3)INFORMATION.
Range
The screen displays Feed Flow, Reject Flow(waste), Product Flow,
and Recovery. Flow Meters must be installed for this screen to dis-
0.00–??
play values.
If the RO is offline/not running, the screen displays FLOW
METERS DISABLE.
G2/G3 only: this screen shows the TDS of the incoming and prod-
uct water as well as the percent rejected. The TDS sensors must
0.00–??
be installed for this screen to display values.
If the RO is offline/not running, the screen displays TDS DISABLE.
When SV3 is selected, the RO controller information screen dis-
0–999
plays the TDS average in ppm. This should be the average TDS-
out value over the last 10 cycles of "TDS Target Time."
Alternate information screen showing recovery, rejection, product
0–??
flow and product TDS.
0.00–??
If the RO is offline/not running, the screen displays FM OR TDS
0–999
DISABLE.
This is the normalized product flow (flow at 77°F)
0.00–??
NOTE: This value is displayed only if the Min NFlow Error limit is
greater than zero.
Incoming (G2 Plus and G3 only) pressure and waste pressure are
shown and the pressure differential (dP) is calculated. The screen
displays DISABLE if no pressure gauges are connected.
If the RO is offline/not running, the screen displays PRESS
GAUGES DISABLE.
The screen displays the temperature of the product water.
Indicates whether the pressure switch, pretreatment lockout, high
float switch or low float switch is open or closed (if installed).
Procedure
Cat. No. 01021713
60