Replace Cordset - Graco InvisiPac GS35 Plug-Free Instruction Manual

Hot melt applicator
Hide thumbs Also See for InvisiPac GS35 Plug-Free:
Table of Contents

Advertisement

Repair

Replace Cordset

Cordset
Replace
Replace
Cordset
See
Fig
14.
Note
There are two types of cordsets (17):
24W087 is for PT100 (385) RTD controlled
guns and 24W088 is for NI 120 Ohm
RTD controlled guns. Ensure you have
the correct cordset before replacing. See
Parts, page
26.
1. Disable gun assembly. See
Before Beginning Repair, page
2. Use a Phillips screwdriver to remove the four
screws (15) and manifold cover plate (52).
3. Use a 2 mm Allen wrench to remove the set
screw (8) holding the cordset (17) on the manifold
(1).
4. Use a Phillips screwdriver to remove the ground
screw (15) and star washer (20) from the
manifold (1).
22
5. Remove the RTD (R) from the manifold (1).
6. Disconnect thermal cutoff (52).
7. Remove the cordset (17) from the manifold (1).
8. Install the new cordset, RTD, and ground (17 in
19.
9. Install set screw (8) against the cordset bushing
Note
On guns that are not low profile,
RTD does not easily pull out, remove the
other cover plate (19) and press out with
a small screwdriver.
the manifold (1). Recrimp thermal cutoff wires.
See
Wiring Diagram, page
Note
Ensure the cordset bushing is fully
inserted into the manifold.
to secure the cordset (17) to the manifold (1).
if the
21, for connections.
3A2805M

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invisipac plug-free gs35

Table of Contents