Flush

Flush
Flush
1. Disconnect or turn off the device which triggers
the solenoid valve.
2. Heat the system to working temperature.
3. Place waste container under the gun to catch the
adhesive.
4. Ensure the nozzle is removed.
5. Press the manual override switch (S) to manually
trigger the solenoid valve.
6. Dispense hot melt (adhesive) until it is clean.
Figure 8
3A2805M

Install Nozzle

Nozzle
Install
Install
Nozzle
Use 1/2 in. wrench to install nozzle. See
Kits and Accessories, page

Select RTD

RTD
Select
Select
RTD
Note
For InvisiPac systems only.
Identify RTD type used in applicator on the system
Advanced Display Module (ADM). The RTD type is
listed on the manifold cover plate. See the InvisiPac
system manual for instructions to configure this
setting.
NOTICE
NOTICE
NOTICE
An incorrect RTD setting will cause the system
to be incapable of maintaining the temperature
setting. The applicator may overheat and trip the
thermal cutoff, if the applicator uses a PT 100 (385)
and NI 120 is selected on the ADM Setup screen.
The applicator may under-heat if the applicator
uses a NI 120 and PT 100 (385) is selected on the
ADM Setup screen.
• If PT 100 (385) is listed, select PT 100 (385) in the
ADM Setup screens.
• If NI 120 is listed, select NI 120 in the ADM Setup
screens.
Installation
44.
11