1
Mount the junction box in a suitable location.
2
Terminate the steel conduits containing the transducer cables as close to the junction
box as possible.
3
Verify that the junction box chassis is not connected to the vessel ground.
If required, use necessary insulation.
4
Remove the insulation on each transducer cable, and connect the individual conductors
to the terminal block.
5
Remove the insulation on each extension cable, and connect the individual conductors
to the terminal block.
6
Verify that you have connected the wires 1:1, and that the colours match.
7
Connect the cable screens the to cable glands in the junction box.
Related topics
Installation summary, page 16
Installing the transducer cable, page 24
Transducer ES38-18/200-18C connection to a GPT transducer socket, page 36
Connecting the transducer cable to the
transceiver
Once the transducer cable has been installed, you can connect it to the transceiver.
Prerequisites
Electrical connections can only be made by skilled personnel (ship electricians, technicians
or engineers). All necessary tools and instruments required must be available.
Context
The ES38-18/200–18C transducer can be used with a variety of echo sounder transceivers.
These use different plugs and connectors.
For specific information about the transducer connection consult the relevant echo sounder
manual.
Procedure
1
Make sure that an ample length of the transducer cable is available for maintenance and
replacement.
404776/A