VII. MAINTENANCE

ANY SERVICING INTERVENTION MUST BE DONE WHEN THE MACHINE IS OFF AND LOCKED

1. SERVICING

Heat transfer press INITIUM ® require little maintenance. To ensure proper operation, follow the
preventive guidelines listed below.
Do not heat objects that could damage or even cut the silicon rubber or damaging the Teflon surface
DAILY :
EVERY 3 MONTHS :

2. QUICK REPAIR ADVICES

SYMPTOMS
No action after turn on the machine
The display screen is working well, but
no temperature increasing on the
heating element.
The display screen show 255℃ once
you power on
The machine is heating during
0~180℃, but display number jumps to
above 200℃ or 300℃ suddenly, or the
numbers on display jumps irregularly
The temperature is out of control: Set
180℃,but the actual temperature is
above 200℃
The setting temp and time becomes
abnormal after exchange the heating
element
Other notice
USE BY QUALIFIED STAFF ONLY
(ELECTRIC AND PNEUMATIC ENERGIES UNPLUGGED)
CHECK that the heating element is clean.
Put a few drops of oil onto the various pivot pins and the pressure
adjusting screw
1). Check the plug whether it connects well or whether it is broken.
2). Check the power switch or digital controller whether it is broken.
3). Check the fuse whether it has been burnt out.
4). Indicating light is on, but no display on screen, check the 5 cable of
Railway transformer. If it's loosening, showing the problem is poor
connection. If they connects well, showing that the Transformer is faulty
1). Check whether the thermocouple of the heating element touches well.
If the thermocouple is loose, the display will show 255℃. and machine
keeps beeping.
2). Check if the indicating light of solid-state relay is on, if not, check if
the relay or digital controller is broken.
3). If you already changed the new solid-state relay but the heating
element still can't heating up, check if the heating element is faulty or the
heating element power cable is loose, need to change by new mug
heater.
1). Check whether the thermocouple is loose or not.
2). If the thermocouple touches is not in loose state, but still show
255℃, then it is faulty.
1). Check whether the thermocouple of the heating element touches well.
2). If the thermocouple is good, It shows that the program of digital
controller is broken, which namely IC or is broken, need to change by
new controller.
1). It means the solid-state relay is broken, out of control, need to
change the relay.
2). Or the digital controller is faulty and it keeps conveying electric to
relay, need to change controller.
1). Please reset the temp and time according the operation process
manual
1). In order to prolong the machine service life, please add the
lubrication oil regularly on the joints.
2). In order to keep the heating element good transfer effect, please
protect it carefully whenever you are using or not.
3). Please keep the machine in dry place.
4). If you are not able to solve the electrical parts problem, please
contact the supplier