V0414 INDEX INDEX ................................2 CONDITIONS OF GUARANTEE ......................3 ASSEMBLY DRAWING ......................... 4 III. Technical Parameters ........................5 USING THE MACHINE ......................... 5 SAFETY ..............................6 INSTALLATION ............................6 CAP HEATER AND PLAIN HEAT PLATEN EXCHANGE .................. 7 OPERATION PROCESS ........................8 SET TEMPERATURE REQUIRED .......................
V0414 I. CONDITIONS OF GUARANTEE The guarantee period starts the day of putting the equipment into service at the user’s place, materialized by the return of the guarantee bill for a duration of one year, 8h per day or 2000 hours. The guarantee is strictly limited to our equipments, against the defects of matter and execution, with the buyer’s responsibility to prove the known defects.
V0414 II. ASSEMBLY DRAWING Upper Hand Wheel Screw Handle Bar Grip Adjusting Screw Power Cord Cap Heater Under Hand Wheel Screw Supporting Holder Plain Under Plate Fasten Screw Plain Heat Platen Fixing Fittings Page 4...
V0414 III. Technical Parameters Model No. iCAP 2 / iLOGO Machine Dimension 380*360*340mm Heating Elements Size one normal cap heater & one 15x 20cm heat platen Printable Articles Max Size 150 x 80mm&150 x 20mm Voltage 220V/1Phase Power 0.5KW for cap press; 0.6KW for heat platen Recommend Setting 180~190C°;...
V0414 1. SAFETY THIS EQUIPMENT IS DESIGNED FOR SINGLE USE ONLY USE BY QUALIFIED STAFF ONLY International Symbols HOT SURFACE ELECTROCUTION RISK DANGER, WARNING You will find most of these symbols on the INITIUM equipment. Important point for security : Don’t touch the hot parts of the equipment while in use.
V0414 3. CAP HEATER AND PLAIN HEAT PLATEN EXCHANGE ④ ② 1. Unplug the power socket , press down the handle bar grip with left hand and release ① screw bolt with right hand. ⑤ 2. Leave the left hand and the cap platen is now lying on the cap under plate ⑥...
V0414 V. OPERATION PROCESS 1. SET TEMPERATURE REQUIRED Turn on power switch. Press button “OK” , the light is Press button “OK”, the temp light The digital display shows on (C denotes Celsius). Press is on. Select with arrows the ۸...
V0414 4. PRINTING METHODS Step 1: Make sure the cord is connected well to the wall socket. Place the cap in the cap heater, and transfer paper with images facing down the cap, adjust moderate pressure, and power on. P.S: use heat resistant tape to fix the transfer paper, make sure transfer paper is exactly attached to cap heater; Step 2: Set the temperature and time required, then temperature starts to rise.
V0414 VII. MAINTENANCE USE BY QUALIFIED STAFF ONLY ANY SERVICING INTERVENTION MUST BE DONE WHEN THE MACHINE IS OFF AND LOCKED (ELECTRIC AND PNEUMATIC ENERGIES UNPLUGGED) 1. SERVICING Heat transfer press INITIUM ® require little maintenance. To ensure proper operation, follow the preventive guidelines listed below.
V0414 3. TROUBLE SHOOTING FOR TRANSFER PRINT QUALITY If the print color is pale: the temperature is too low / the pressure is not correct / or not pressed long enough. If the print color is too brown or the transfer paper is almost burnt: reduce the setting temperature. ...
Need help?
Do you have a question about the Initium iCAP 2 and is the answer not in the manual?
Questions and answers