HART

23.3 Device-Specific Commands

The following device-specific commands are implemented:
Command Number Description
23. Appendix 5 –
Commands Used
®
128
Read Gas Table Name
129
Read available Gas Table Name
130
Write Gas Table Index
132
Read Event Log history
133
Read Diagnostics (Warnings or faults)
135
Simulate Alarm or Warning or Fault
138
Write Alarm1 threshold
139
Read Alarm1 threshold
140
User Authentication
142
Password change
143
Enter/Exit Inhibit mode
146
Bump Test
147
Read Field Data
149
Read Real Time Clock
150
Write Real Time Clock
151
Read HART communication status during device fault
152
Write HART communication status during device fault
153
Read Inhibit current
154
Write Inhibit current
155
Read Warning current
156
Write Warning current
157
Read Over range current
158
Write Over range current
159
Clear latched faults and logged faults (partial or full)
160
Read Current operating mode
Searchpoint Optima Plus with optional HART