RUGGEDCOM RS8000
Installation Guide
that during a transient electrical event, communications errors or interruptions may occur, but recovery is
automatic.
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across
distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground
fault conditions.
CONTENTS
•
Section 1.5.1, "Supported Fiber Optic Cables"
Section 1.5.1
Supported Fiber Optic Cables
The following fiber optic cable types are supported under the stated conditions.
Cable Type
OM1 (62.5/125)
OM2 (50/125)
a
OM3 (50/125)
a
OM4 (50/125)
a
Laser optimized.
Supported Fiber Optic Cables
Modal Bandwidth
Wavelength (nm)
(MHz·km)
850
1300
850
1300
850
1300
850
1300
100Base-FX
200
—
500
2000
500
—
500
2000
1500
—
500
2000
3500
—
500
2000
Introduction
Distance (m)
1000Base-SX
10GBase-SR
275
33
—
—
550
82
—
—
550
300
—
—
550
400
—
—
Chapter 1
5