Connecting The Failsafe Alarm Relay - Siemens RUGGEDCOM RS8000 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS8000:
Table of Contents

Advertisement

RUGGEDCOM RS8000
Installation Guide
Figure 4: Panel Mounting
1. Screw    2. Panel/DIN Rail Adaptor
2.
Install the supplied screws to secure the adapters to the panel.
Section 2.3

Connecting the Failsafe Alarm Relay

The failsafe relay can be configured to latch based on alarm conditions. The NO (Normally Open) contact is closed
when the unit is powered and there are no active alarms. If the device is not powered or if an active alarm is
configured, the relay opens the NO contact and closes the NC (Normally Closed) contact.
NOTE
Control of the failsafe relay output is configurable through ROS. One common application for this relay
is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for
the RUGGEDCOM RS8000.
The following shows the proper relay connections.
Connecting the Failsafe Alarm Relay
1
2
1
Chapter 2
Installing the Device
1
2
1
11

Advertisement

Table of Contents
loading

Table of Contents