5.2.3. fixed outputs - dry contacts

5.2.3.1. Description
As standard, the SIRCO MOT PV is equipped with four fixed outputs located on
the motorisation module.
(Dry contacts to be powered by the user).
5.2.3.2. Position auxiliary contact
The SIRCO MOT PV is equipped with integrated position (I – O) auxiliary contact outputs through 3 off micro switches.
pins 13, 04, 24
(Normally Open contacts with pin 13 as common)
5.2.3.3. SIRCO MOT PV Product available output (motorisation)
pin 63a – 64a
(Normally Open contact that is held closed when the motorisation is available).
This contact gives constant feedback about the product's availability and it's capacity to operate.
The SIRCO MOT PV performs a self diagnostics test on the motorisation module at startup, when put from Manual
-> Auto and then every 5 minutes. This test ensures that the SIRCO MOT PV is operational in terms of control inputs.
Should one of the tests fail, a second test is performed to reconfirm the error state. Should the SIRCO MOT PV
motorisation module become unavailable, contact 63A – 64A are opened, the power/ready LED's are switched off,
and the fault LED is activated. The fault LED will remain active for as long as sufficient power is available and the fault
condition is not reset. The fault is reset when the product is switched from AUT -> Manual -> Auto mode.
SIRCO  MOT  PV (Motorisation) Product Available / Unavailable Watchdog relay will open for any of the following
reasons below: For added security, "Product Availability" is informative and does not necessarily inhibit motor
operation.
ProductUnavailable+WarningLEDCondition:
Product in manual mode
Motor not detected (Autotest)
Control voltage out of range
Operating factor fault active (N° of operations / min)
Powerfail active
Customer input autotest failed
Invalid product customisation
Abnormal switching when not in manual mode
Requested position not reached
Locked mode active when not in manual mode
External Fault -> User input
Unexpected current flowing through the motor when idle
Sampling rate for the above is every 10 ms
Exception: motor detection sampling rate is every 5 min
28
EN
1
2
75A413
200A
75A414
250A
75A415
400A
75A416
500A
75A417
630A
75A425
200A
75A426
250A
75A427
400A
75A428
500A
75A429
630A
75A430
I800A
75A431
1000A
75A432
1250A
75A433
1600A
75A434
2000A
75A436
3200A
3
4
Ue 750V
19PV3020
Ue 750V
19PV3025
Ue 750V
19PV3040
Ue 750V
19PV3050
Ue 750V
19PV3063
Ue 1000V
19PV4020
Ue 1000V
19PV4025
Ue 1000V
19PV4040
Ue 1000V
19PV4050
Ue 1000V
19PV4063
Ue 1000V
19PV4080
Ue 1000V
19PV4100
Ue 1000V
19PV4120
Ue 1000V
19PV4160
Ue 1000V
19PV4200
Ue 1000V
19PV4320
SIRCO MOT PV - 543 544 B - SOCOMEC