Fresh Water; Bonding System Maintenance; Water Tank; Water Pump - Back Cove Yachts Back Cove 30 Owner's Manual

Table of Contents

Advertisement

P. Bonding System Maintenance
The sacrificial zinc anodes on the hull, trim tabs, and
rudder (and prop shaft, if installed) should be
inspected periodically, replaced as necessary and
never painted. It is normal for the sacrificial zinc
anodes to appear "corroded" and decrease in size
over time.
A properly functioning bonding system will essentially
join all the metals. A broken or corroded connection
will break this bond and may result in accelerated
corrosion. Inspect the system with a multi-meter to
determine any differences in potential between
fittings or high resistance in the wiring or connections.

7.4 Fresh Water

A. Water Tank
The roto-molded polyethylene water tanks (see
Fig_6.3-4) have a deck-fill plate located to starboard.
(see Fig_6.3-1) Each is vented through a flush SS
fitting in the side deck (port and starboard). The sides
and top panels of the water tank are somewhat
flexible, and can expand outward when the tank is
full. The tank is not designed to be pressurized.
Pressurization from overfilling can result in leaking.
(Fig_6.3-4)
Note:
The water tanks are connected through a hose
run on the aft engine room bulkhead. Fill tanks
slowly to allow each tank to fill equally. Filling
tanks too quickly will cause uneven tank load
which will affect the boats trim.
B. Water Heater
The water heater is located on the starboard side in
the engine room, forward of the water (starboard)
tank.
(Fig_6.3-2)
The water heater heats domestic fresh water with
either an electric heating element or by using engine
jacket water. (see Fig_6.3-2) The water heater must
be properly commissioned before use, as outlined in
the
commissioning
manufacturer's
recommendations
information.
The water heater must be filled with water before
switching "ON" the electric heating element.
Operating the water heater without water will
cause the electric heating element to fail.
Scalding may occur due to overheating the
domestic water after the engine has been run for
some time. Always exercise care when running
hot water.
C. Water Pump
(Fig_6.3-3)
The Water pump is located on the starboard side of
the engine room, aft of the water (starboard) tank.
(see Fig_6.3-3)
The water pump is sized to assure adequate water
flow and have minimum surging as it cycles. When
the system senses a need for water the pump will
immediately start. Use of only one faucet at a time is
recommended.
checklist.
Refer
to
for
additional
the

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents