Daikin ATKC09RV2S Service Manual page 12

1.5/2.0/2.5/3.0/3.5 kw class 9000/12000 btu/h class

Advertisement

Swing Motor / PCBs
Step
3. Remove the display/
signal receiver PCB.
1
Unfasten the hook and
release the display/
signal receiver PCB
ASSY.
2
Turn over the display/
signal receiver PCB
ASSY.
3
Unfasten the 3 hooks
and remove the display/
signal receiver PCB.
4
Disconnect the
connector [S27].
4. Remove the control PCB.
1
Lift the shield plate (2)
and unfasten the 2
hooks.
2
Slide the shield plate
(2) and remove it.
10
Procedure
Display/signal receiver PCB ASSY
Hook
Hook
ON/OFF button
(Forced cooling operation
ON/OFF button)
TIMER lamp
Hook
(R23307)
Display/
signal
receiver
PCB
(R23308)
[S27]: control PCB
[S27]
Operation lamp
Signal receiver
(R22350)
Shield plate (2)
(R23309)
Si041264EC