test at power-up feature which verifies the integrity of the system. Various
162Bug routines that handle I/O, data conversion, and string functions are
available to user programs through the TRAP #15 system calls.
N
MVME162Bug occupies the first half (512KB) of Flash
ote
memory.

MVME712 Series Transition Modules

The MVME712 series transition modules provide an interface between the
MVME162 and peripheral devices such as EIA-232-D serial devices, SCSI
devices, and LAN Ethernet devices. A P2 Adapter Board or LCP2 Adapter
Board and cable are required.
C
Connect peripheral devices to MVME712 serial ports 2 and
aution
4 only. (Serial port 2 is the terminal or bug interface.) Do
not connect peripheral devices to serial ports 1 and 3, or to
the printer port.
An I/O device may be connected to serial port 1 (or 2) on the
MVME162 or to serial port 2 (or 4) on the MVME712, but not
to both ports. (That is, if an I/O device is connected to
MVME162 port 1, no other I/O device should be connected
to MVME712 port 2; they are functionally the same port.)

Available Software

Available software for the MVME162 includes the on-board
debugger/monitor firmware, VMEexec driver packages for various
IndustryPack modules, and numerous third-party applications for MC680x0-
based systems. Contact your local Motorola sales office for more information.
MVME162/D2
Required Equipment