The 8-bit configuration register data is passed to the ADXL180
with a read/write command bit, a 4-bit configuration register
address, and a parity bit as shown in Figure 37. The read/write
bit is set to indicate the desired action. A 0 indicates a write
Table 42. Configuration Mode Transmit Data Bit Mapping
DB15
DB14
DB13
DB12
Parity
Addr 3
Addr 2
Addr 1
RECEIVE DATA FRAME (14 BITS)
TRANSMITTED
FIRST
DATA
0
1
2
3
Figure 37. Configuration Mode Command (Receive) Data Frame
DB11
DB10
DB9
DB8
Addr 0
Data
Data
Data
Bit 7
Bit 6
Bit 5
(MSB)
Rev. 0 | Page 46 of 56
operation and a 1 indicates a read operation. The parity bit is set
for even parity. The parity bit should be set to 0 or 1 to make the
total number of 1s in the data frame even. The data is
transmitted LSB first as shown in Table 42.