Influence of MD On Data Range
Table 23. MD Settings and Device Data Ranges
Mode (Device Data)
0: ADIFX
3
(All Configuration Data, Serial Number, and
Manufacturer ID)
1: Range Data Only
3
(Limited Range Selection)
3
2: 8-Bit Coded Device Data
(UD[7:0], Serial Number, and Range)
4
3: 10-Bit Coded Device Data
(UD[7:0], Serial Number, and Range)
1
SVD is the state vector disable configuration bit.
2
AZE is the auto-zero enable configuration bit
3
If Phase 2 Mode 0, Mode 1, or Mode 2 is selected, the device data is 8-bit data. If the 10-bit data mode is selected in combination with Phase 2 Mode 0, Mode 1, or Mode
2, the 8-bit device data is left justified in the 10-bit data field. The two LSBs are held at zero (see Table 24).
4
The 10-bit device data mode (Phase 2 Mode 3) is incompatible with the 8-bit data mode (the DAT bit is set to 1). The device transmits a configuration error code if
Phase 2 Mode 3 is selected and the DAT bit is set to 1. No sensor data is transmitted.
Device Data Mapping in Phase 2
Table 24. Phase 2 Device Data Bit Mapping in 10-Bit Sensor Data Mode
DB9
DB8
DB7
Device
Device
Device
Data MSB
Data
Data
Table 25. Phase 2 Device Data Bit Mapping in 8-Bit Sensor Data Mode
DB7
DB6
Device Data MSB
Device Data
MD1
MD0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
1
0
1
0
1
0
1
0
1
1
1
1
1
1
1
1
DB6
DB5
Device
Device
Data
Data
DB5
DB4
Device Data
Device Data
Rev. 0 | Page 27 of 56
1
2
SVD
AZE
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
0
0
0
1
1
0
1
1
DB4
DB3
Device
Device
Data
Data
DB3
DB2
Device Data
Device Data
ADXL180
Data Range
Full
Reduced
Configuration error
Configuration error
Full
Reduced
Reduced
Reduced
Full
Reduced
Reduced
Reduced
Full
Reduced
Reduced
Reduced
DB2
DB1
Device
0
Data LSB
DB1
DB0
Device Data
Device Data LSB
DB0
0