Form 6-LS Pole Mount Recloser Control Installation and Operation Instructions
Standard
(No Communication Option)
#2
J4 – ETHERNET – J3
IRIG-B
J5
2
1
Ethernet 10/100 Base-T
Type 1
Figure 26.
Back panel Ethernet and Communication options.
The Ethernet communication card accessory is offered in 3
physical layer configurations (twisted pair and optical-fiber
options) as shown in Table 10.
TABLE 10
Ethernet Communication Card Configurations
Card
Type Configurations
1
10/100 Base-T
2
100 Base-FX
(multi-mode fiber)
3
10/100 Base-T,
100 Base-FX
4
100 Base-FX,
(single-mode fiber)
Maximum link length is determined by the use of the
particular physical layer implementation, and can be further
constrained by the actual network configuration. In case of
the 100Base-FX MT-RJ connector based implementation,
maximum link length in excess of 2000m can be achieved
with 62.5/125µm multi mode fiber. The fiber-optic link uses
1300nm wavelength, and can easily be interfaced to other
100Base-FX solutions (ST connector patch cord solution).
The Ethernet communication accessory card (Figure 26) is
equipped with two physical ports configured to act as
primary and standby LAN connections. Availability of the
backup communication port enables creation of highly
redundant Ethernet networks thus increasing the overall
system reliability.
Note:
Under normal network conditions, all communications
will be channeled through the primary port (#1, Figure
26), with the standby port either logically disabled, or
configured for fast automatic throw-over in case of the
primary Ethernet link failure. Refer to Service Information
S280-70-4 (ProView 4.X.X) or S280-70-21 (ProView
5.X.X) Form 6 Microprocessor-Based Recloser Control
Programming Guide for additional Ethernet accessory
configuration information.
36
RS-485 Communication
TX
IRIG-B
J5
#1
#2
J4 – ETHERNET – J3
IRIG-B
J5
2
1
Ethernet 100 Base-FX
Type 2
Output
Communication
Connectors
Speed
2 * RJ-45
10 / 100MBps
(auto switching)
2 * MT-RJ
100MBps
(full duplex)
RJ-45 + MT-RJ
10/100MBps
and 100MBps
2 * LC
100MBps
(full duplex)
Serial Fiber
+
RS-485 C
-
RX
IRIG-B
J5
#1
#2
J4 – ETHERNET – J3
IRIG-B
J5
2
1
Ethernet 10/100 Base-T,
100 Base-FX
Type 3
CAUTION: Equipment misoperation. Do not
connect this control to an energized recloser until
all control settings have been properly programmed and
verified. Refer to the programming information for this
control. Failure to comply can result in control and
recloser misoperation, equipment damage, and personal
injury.
IMPORTANT: The Form 6 control can be taken out of
service for testing and placed back into service without
de-energizing its recloser and interrupting the system.
However, during the time the control is out of service,
the recloser is inoperative.

Testing an Installed Control

The following tests to determine initial operation of the
Form 6-LS control can be performed while connected to
an operating recloser.
Note:
These are the only tests performed on an installed, oper-
ating control.
1. Verify operating status of all indicator lights by pressing
and holding the LAMP TEST key for two seconds on
the programming panel (Figure 27).
2. Check the operational values for currents, voltages,
and other metering information.
Note:
Scroll through the LCD display messages by press-
ing the  and  cursor movement arrows under-
neath the LCD display on the programming panel
(Figure 27).
3. Test battery operation as follows:
Note:
The battery test is blocked for 30 seconds upon
power up of the control.
Note:
AC power can be either connected or disconnected
for battery test.
(continued on next page)
RX
TX
NON-ECHO
IRIG-B
J5
#1
#2
J4 – ETHERNET – J3
2
1
Ethernet 100 Base-FX
Type 4

TESTING

#1
Default
Primary
Ethernet
Interface
IRIG-B
J5
G110.3