Accessories; Loop Sectionalizing Accessories; 120 Vac Gfi Duplex Outlet; Discrete Interface Board Option Accessory - Cooper F6-PA-LS Installation And Operation Instructions Manual

Form 6-ls microprocessor-based pole mount recloser control
Table of Contents

Advertisement

These accessories are available. Contact your Cooper
Power Systems representative for additional information.

Loop Sectionalizing Accessories

Various wiring options for 120 VAC low voltage closing
reclosers or control-powered NOVA reclosers, 120 VAC
single or three-phase sensing are available. Refer to Table
8 for ordering options.
TABLE 8
Loop Sectionalizing Accessories
Description
Wiring Options for 120 VAC Low-Voltage Closing Reclosers, 120 VAC Single- or Three-Phase Sensing
Junction box equipped with Source 1 and Source 2 sensing cables. (4-conductor, 5 ft. length) includes
hardwiring the low-voltage closing cable for the recloser (KA11ME1-X) and hardwiring the sensing/low
voltage cable for the control (KA145LS-X) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA235LS1*
Input-sensing/low voltage cable, 8 conductor, 120 VAC (basic cable, no length) . . . . . . . . . . . . . . . . . . . . . . . . . KA145LS
Replace "X" with desired length. Select from 5 to 80 feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA145LS-X
120 VAC/240 VAC Input receptacle, 8-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KME6-805-1
Wiring Options for Control-Powered NOVA recloser, 120 VAC Single- or Three-Phase Sensing
Junction box equipped with Source 1 and Source 2 sensing cables. (4-conductor, 5 ft. length) includes
hardwiring the sensing/low voltage cable for the control (KA145LS-X) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA235LS1**
Input-sensing/low voltage cable, 8 conductor, 120 VAC (basic cable, no length) . . . . . . . . . . . . . . . . . . . . . . . . . KA145LS
Replace "X" with desired length. Select from 5 to 80 feet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KA145LS-X
120 VAC/240 VAC Input receptacle, 8-pin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KME6-805-1
*Requires KA11ME1-X cable, ordered with recloser. KA145LS-X cable and the KME6-805-1 receptacle are to be ordered separately.
**KA145LS-5X cable and the KME6-805-1 receptacle are to be ordered separately.

120 VAC GFI Duplex Outlet

The GFI Duplex Outlet (Catalog Number KME6-1776-2) is
available for controls powered by 120 VAC three-wire sup-
ply power. This convenience outlet is rated for 15 Amperes
and is accessible through the front door in the control
cabinet. The 120 VAC GFI Duplex Outlet is used for many
applications such as power for the MET Tester, auxiliary
measurement equipment, and supplemental lighting.
Discrete Interface Board (DIF)
Option Accessory
A Discrete Interface Board Option accessory provides
eight configurable input control contacts and eight configu-
rable output status contacts (Figure 24). The ordering
options include: Standard (3 inputs / 5 outputs) or
Additional (8 inputs / 8 outputs).

Cabinet Ordering Accessories

• AISI 304 stainless steel cabinet construction
• Three-point door latch

ACCESSORIES

Cable Locking Sleeves

To prevent detachment of the control cable from the con-
trol cabinet by unauthorized personnel, a cable-locking
sleeve is available to enclose the cable plug. The plug is
passed through the sleeve and the sleeve is then fastened
from inside the control cabinet. There is no access to the
cable receptacle without opening the locked cabinet door
and detaching the sleeve.
Catalog Number KME6-1772-1: Quantity 1
Catalog Number KME6-1772-2: Quantity 2
Figure 24.
Form 6-LS control discrete interface board
accessory.
S280-70-10
DIF Board Accessory
CI1
CI2 CI3 SS1
CO1
CO2 CO3 CO4
1
3
5
7
9
11
13
15
17
19
J1-RS-232
TB1
RS-232 DTE
2
4
6
8
10
12
14
16
18
CI1 CI2
CI3 SS1 CO1 CO2 CO3 CO4
CI4
CI5 CI6
CI7 CI8 CI9 CI10 CI11 CO5
CO6
CO7 CO8 CO9 CO10
1
3
5
7
9
11
13
15
17
19
21
1
3
5
TB3
2
4
6
8
10
12
14
16
18
20
2
4
6
CO7 CO8 CO9 CO10 CO11CO12
CI4 CI5 CI6
CI7 CI8 CI9 CI10 CI11 CO5 CO6
TB9
+
28 VDC
WHETTING VOLTAGE
P1
P2
P3
1
3
1
3
1
3
23 22
21
20 19
18 17
16
15 14
24
1
2
3
4
5
2
4
2
4
2
4
12
11 10
9
8
7
6
5
4
3
2
VOLTAGE SENSING
53VDC
CONTROL CABLE
Catalog Number
RS-485
C + –
IRIG-B
CO11 CO12
7
9
11
13
TB4
8
10
12
P4
1
2
3
4
5
13
1
2
3
4
5
1
28 VAC
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

F6-pb-ls