4.2 Regulation for LPG

Loosen screw A and push air
regulator B to the bottom.
With a 7 mm wrench, remove nozzle
C and replace it with the proper one
(follow
reference tables for the type of gas
to be used).
The torque wrench setting of the
nozzle must not exceed 3 Nm.
Regulate the air by sliding regulator
B until reaching distance "X" shown
in the table in paragraph "4.4
Regulation of primary air".
Lock
screw A.
Burner
Auxiliary
Semi rapid
Rapid
Wok
4.3 Adjustment for natural gas
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
To allow the unit to work back with this type of gas, after it has been
adjusted for LPG, perform the same operations described in paragraph
"4.2 Regulation for LPG", but choose the nozzles and regulate the
primary air for natural gas, as shown in the following table and in
paragraph "4.4 Regulation of primary air".
Burner
Auxiliary
Semi rapid
Rapid
Wok
12
Instructions for the installer
the
instructions
regulator
B
by
Nominal gas
consumption
Nominal gas
consumption
on
the
tightening
LPG – 2.75 kPa
Turn-down gas
consumption
(MJ/h)
5.3
6.6
9.0
15.0
NG – 1.0 kPa
Turn-down gas
consumption
(MJ/h)
5.3
6.6
9.0
15.0
Injector
(MJ/h)
1.5
1.5
3.2
5.4
Injector
(MJ/h)
1.4
1.4
2.4
4.3
(mm)
0.62
0.70
0.82
1.05
(mm)
1.00
1.15
1.35
1.75