6.2 Regulation for LPG

Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B so that nozzle C is covered perfectly.
Move the Venturi tube D to regulate the air flow until distance "X" is
reached indicated in the chart in paragraph "5.4 Regulation of primary air"
and then secure the tube by means of screw A. After the regulations
have been carried out, restore the seals with sealing wax or equivalent
material.
Burner
Auxiliary (1)
Semi-rapid (2)
Average rapid (3)
Double crown
internal (4)
external (4)
Instructions for the installer
Rated
heating
capacity
(kW)
1.05
1.65
2.55
0.8
3.3
LPG – G30/G31 28/37 mbar
Nozzle
Reduced
diameter
flowrate
1/100 mm
(W)
48
380
62
380
76
650
42
380
87
1200
Flowrate
Flowrate
g/h G30
g/h G31
76
75
120
118
185
182
84
82
276
271
31