8.4. Operating elements

8.4.1. Operating/Programming Mode: Jumper J1

Jumper J1 is used to configure the operating and programming mode of the ID ISC.M02.
In standard operation the jumper is set to Position 1-2 (see Fig. 4.3.1-1). The reader is then in
normal operating mode.
If the jumper is set to Position 2-3, the integrated hardware bootloader starts after a reset. Since
the reader's firmware however also has a software bootloader, the hardware bootloader option
should be used only for installing the software bootloader.
For additional information about programming the reader, see the corresponding Application Note
„Firmware Update".
Jumper position
1 - 2
2 - 3
Table 3.4.1-1: Jumper J1
Bild 3.4.1-1: Jumper J1
FEIG ELECTRONIC GmbH
Installation
Mode
Standard setting :
The reader is in normal operating mode.
Activation of the hardware bootloader:
After a reset the reader's CPU starts its hardware
bootloader, which can then be used for new pro-
gramming.