8.2.1. Supply voltage

The ID ISC.M02-A/B must be supplied only by a regulated power supply.
If switching power supplies are used with the module, be sure that there is adequate filtering.
Noise from the power supply can result in a reduction of the read/write range of the module.
The cable length from the power supply should be as short as possible, and should in any case not
exceed 3 m.
Pin no.
*
**
Table 3.2.1-1: Pin assignments for X1
NOTE:
• Reversing the polarity of the supply voltage may destroy the device.
• Supply voltages outside the specifications may destroy the device.
FEIG ELECTRONIC GmbH
X1
Function
8
VCC *
9, 4
GND **
Use only regulated power supplies !
GND-Pins 4 and 9 are to be connected directly to each
other on the Reader Module
Page 30 of 42
Installation
Description
ID ISC.M02-B
+ 5 V DC ± 5%
GND
ID ISC.M02
M20301-0de-ID-B.doc