ADVAncED PARAMETERS
POWER AND ENERGY REPORTING CONFIGURATION
60. Measuring power consumed by the device itself
This parameter determines whether the power metering should in-
clude the amount of active power consumed by the device itself.
Available settings: 0 - function inactive
Default setting:
61. Power reports - on change
This parameter determines the minimum change in consumed power
that will result in sending new power report to the main controller.
For loads under 50W, the parameter is not relevant and reports are
sent every 5W change.
Power report are sent no often then every 30 seconds.
Available settings: 0 - reports are disabled
Default setting:
62. Power reports - periodic
This parameter determines in what time intervals the periodic power
reports are sent to the main controller. Periodic reports do not de-
pend on power change (parameter 61).
Available settings: 0 - periodic reports are disabled
Default setting:
65. Energy reports - on change
This parameter determines the minimum change in consumed ener-
gy that will result in sending new energy report to the main controller.
Available settings: 0 - reports are disabled
Default setting:
66. Energy reports - periodic
This parameter determines in what time intervals the periodic energy
reports are sent to the main controller. Periodic reports do not de-
pend on energy change (parameter 65).
Available settings: 0 - periodic reports are disabled
Default setting:
1 - function active
0
Parameter size:
1-500 (1-500%) - change in power
15 (15%)
Parameter size:
30-32400 (30-32400s) - report interval
3600 (1h)
Parameter size:
1-500 (0.01 - 5 kWh) - change in energy
10 (0.1 kWh) Parameter size:
30-32400 (30-32400s) - report interval
3600 (1h)
Parameter size:
1 [byte]
2 [bytes]
2 [bytes]
2 [bytes]
2 [bytes]