Configuring The Transmit Delay Bound - SMC Networks SMC6709L2 Management Manual

Tigerswitch 10/100 8-port fast ethernet switch
Hide thumbs Also See for SMC6709L2:
Table of Contents

Advertisement

Configuring the Transmit Delay Bound

Use the "Max bridge transmit delay bound" page to set the maximum
queuing delay.
Field Attributes
• Max bridge transmit delay bound – Limits the time packets can be
queued in switch. If enabled, packets queued beyond the specified time
will be dropped. (Range: OFF, 1, 2, 4 seconds; Default: OFF)
• Enable Delay Bound – Enables a transmit delay for packets in the
low-priority queue. When enabled, any low-priority packets that exceed
the delay bound will be sent. Note that the "Max bridge transmit delay
bound control" must be enabled for the Enable Delay Bound to function.
• Max Delay Time – Sets the maximum queuing time for low-priority
packets. Any low-priority packets that exceed the delay bound will be
sent if the Enable Delay Bound is on. (Range: 0-255 ms; Default: 0 ms)
Console – Click Switch Static Configuration=>Misc Configuration=>
Max bridge transmit delay bound. Specify the maximum transmit delay
bound for the overall delay permitted within the switch, enable or disable
the delay bound for the low-priority queue and set a value for this bound,
then save your settings.
TigerSwitch 10/100 :
=====================
actions->
Arrow/TAB/BKSPC = Move Item
S
WITCH
Configure Max Bridge Transmit Delay Bound
Max bridge transmit delay bound :OFF
Enable Delay Bound :Disabled
Max Delay Time :0
<Edit>
Select the action menu.
Quit = Previous menu
S
C
TATIC
ONFIGURATION
<Save>
Enter = Select Item
M
<Quit>
4-33
ENU