Heating Element; Control Box & Electrical Components - Pitco SELV14 Installation & Operation Manual

Reduced oil volume frying system
Hide thumbs Also See for SELV14:
Table of Contents

Advertisement

INSTALLATION & OPERATIONAL SELV MANUAL

12.1.5 HEATING ELEMENT

 Check if the element is mechanically strong and in good condition. Look for scale build up and
inspect for signs of dry firing.
 Verify element wires are in good working condition. Look for damage to wires or frayed
insulation. Check that the insulation is dry.
 Verify that bulkhead connections/nut is tight and leak free. Look for grease build up and oily
surfaces.
 Verify amp-draw is within range as compared to the information on the data plate.
12.1.6 CONTROL BOX & ELECTRICAL COMPONENTS
 Verify that heating contactors are in good condition. Check for worn or pitted contacts. Verify
that wires are tight and in good condition.
 Verify that all components (transformer, terminal block, relays, drain switches, etc...) are in
good condition. Verify that wires are tight and in good condition.
 Verify enclosures are free of leaks. Check for water stains and wet surfaces.
 Verify that the covers and panels are intact and provide a safe condition. Check for loose parts.
 Verify power cord is in good condition. Check for frayed or exposed wires. Verify that the
insulation is in good condition and the attachment to the appliance is tight.