INSTALLATION INSTRUCTIONS
FITTING THE COPING ON OCTO POOLS
> >
60
The coping comprises 8 interior planks and 8 exterior planks. Arrange the planks on the the support brackets as shown.
The interior planks overlap the pool by approximately 25 mm from the edge of the wall. Make sure that the elements are
correctly positionned around the periphery of the pool.
The coping is approximately 295 mm wide with a gap of around 5 mm between the interior and exterior planks
62
Attach the coping elements to the mounting plates on
the support brackets using roofing screws (bag G and H)
as shown. Pre-drill lightly to ease driving of the screws.
Check continuously that the coping elements are correctly
aligned.
64
All that remains is to attach the 8 coping corner connecting
brackets (mounting kit in the coping pack) as shown above,
taking care to position the brackets correctly .
18
proswell.fr
/ OCTO & OCTO+
61
63
In the case of a skimmer, the outer coping plank anove the
skimmer is attached to the inner plank by means of 2 hinges
(bag A). It is not screwed to the support brackets. The hinge
allows access to the skimmer basket. After use, secure the
latches. (See below).
65
In the case of a skimmer, mount the latches (bag N) as
shown.