Collecting Data; Memory; Setting Recording Parameters; Logging Rates - Topcon HiPer VR Operator's Manual

Hide thumbs Also See for HiPer VR:
Table of Contents

Advertisement

Collecting Data

This chapter provides general information about memory, recording data, downloading data, and
removing files to free up memory space.

Memory

The HiPer VR is equipped with an internal 8 GB memory card. The memory card is formatted as FAT32.
To access the raw data files on the memory card, see "Managing Files".

Setting Recording Parameters

You can use one of the following ways to set logging parameters, such as logging rate, types of
messages, and so forth.
Topcon Receiver Utility (TRU) software
MAGNET Field software

Logging Rates

Memory usage for data logging depends on the logging rate. For more information about setting logging
rate parameters, see the

Recording Data

You can log GNSS Raw data to the receiver's memory card, and use the Topcon Receiver Utility (TRU)
or MAGNET Office™ software to download the files to a computer.

Recording Data via the LED Display Panel

To start recording data, using the LED display panel:
1. Press the Power button to turn on the receiver.
2. Wait for the Power LED to become solid green. The receiver is now available to log the raw data.
The receiver is not available to log the raw data until the startup procedure is
completed.
3. Press the Power button three times in a row within 2 seconds to start recording.
4. Make sure the REC light blinks green, which indicates a "*.tps" file has opened and data collection
has started. The REC LED blinks each time data is saved to the internal memory. If the REC light
blinks red, the receiver has either a hardware problem, or an improper OAF. See "Option
Authorization Files" for more information.
Memory
TRU Online Help
.
P/N: 1023998-01
7-1