LEVEL DIAGRAM
Receiver section
5
RF (Center Frequency)
- 120dBm
- 121dBm
- 123dBm
D310
ANT
D311
D312
C372 D313 C562
ANT
LPF
BPF
4
Transmitter section
3
AF (1kHz)
5mVrms
IC902
2
SSI
MIC
CODEC
1
A
B
- 111dBm
- 110dBm
C549 Q502 C545
C522 IC500 C500 XF600 C663 Q604 C658 Q603 C653
BPF
BPF
RF AMP
MCF
RX VCO/ PLL
To make measurements in the AF section, connect the AC level meter.
(ANT input: -53dBm, 1kHz FM, 1.5kHz DEV (Narrow). SP output: 4W@4ohm Load)
In the RF section, use 470pF coupling capacitor.
(The display shows the SSG input value required to obtain 12dB SINAD.)
AF
(1kHz)
f1:115.2mVrms
f1:0dBm
f2,f3:139.3mVrms
f2,f3:2.8dBm
IC706
IC902
C150
Q107
C185
SSI
VCO
Coupler
CODEC
To PLL IC
C
(No.RA017<Rev.003>) 2-12
1st IF (49.95MHz)
- 117dBm
-113.5dBm
- 106dBm
IF IC
IF AMP
IF AMP
IC600
RF (Center Frequency)
4 dBm
15dBm
17dBm
L134
L135
C304
IC300
C312
Q300
C334 IC302
Pre-
Drive
Drive
f1: F,K (Center frequency: 485MHz)
f2: F2,K2 (Center frequency : 425MHz)
f3: E (Center frequency : 435MHz)
D
E
2-12 (No.RA017<Rev.003>)
AF (1kHz)
141mVrms
IC706
IC902
C927 IC903
SSI
CODEC
C944 IC911 C969
28.8mVrms
f1,f2:47.7dBm
f1,f2:45W
f3:45dBm
f3:25W
f1,f2:47.5dBm
f3:44.8dBm
ANT
C350
C372
Final
ANT
LPF
F
116 mVrms
IC713
VOL