Item
Condition
Panel tuning
mode
[Analog
1) Adj item:
Narrow]
[An ADEV]
Adjust:[****]
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
*2 : Refer to the "4.19.1 Necessary Deviation adjustment item for each signaling and mode" table.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
14. P25
1) Adj item:
High
[P1 PDEV]
Devia-
Adjust:[****]
tion
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
1-88 (No.RA017<Rev.003>)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Devia-
[Maxmum Devia-
tion
tion (Analog Nar-
meter
row)]
Oscil-
2) Adj item:
lo-
[Low1]→
scope
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item:
Devia-
[P25 High Devia-
tion
tion]
meter
Deviation meter
Oscil-
LPF: 3kHz
lo-
HPF: OFF
scope
2) Adj item:
[Low1]→
[Low3]→
[Low5]→
[Center1]→
[Center3]→
[Center5]→
[High2]→
[High4]→
[High6]
Press [Transmit]
button.
Press [Apply All]
button to store the
adjustment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Adjustment
Method
Write fixed value for
2050~2150Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 2050Hz and
store the
2150Hz.
adjustment
Deviation meter
value after all
LPF: 15kHz
adjustment
HPF: OFF
points have
been adjusted.
499
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Write fixed value for
2771~2883Hz
each adjustment point.
(The value is written be-
[PC test
low.) Transmit at each
mode]
adjustment point and
Press [Apply
check that the deviation
All] button to
is between 2771Hz and
store the
2883Hz.
adjustment
Deviation meter
value after all
LPF: 3kHz
adjustment
HPF: OFF
points have
been adjusted.
504
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
Specifica-
tions
/Remarks

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Nx-5800b