Download Print this page

Kenwood NX-5800 Service Manual page 100

Uhf digital transceiver
Hide thumbs Also See for NX-5800:

Advertisement

4.19.1 Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following
example. In the case of the signaling "QT (Analog Wide 5k)", this signaling is composed of three elements [Balance, Maximum Devi-
ation (Analog Wide 5k) and QT Deviation (Analog Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before
adjusting QT Deviation (Analog Wide 5k).
Mode Signaling
Analog Audio
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
QT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. QT Deviation [Analog
Wide 5k]
DQT
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DQT Deviation [Analog
Wide 5k]
LTR
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. LTR Deviation [Analog
Wide 5k]
DTMF
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. DTMF Deviation [Analog
Wide 5k]
2TONE
1. Balance adjust
2. Maximum Deviation
[Analog Wide 5k]
3. Single TONE Deviation
[Analog Wide 5k]
MSK
1. Balance adjust
(Fleet
2. Maximum Deviation
sync)
[Analog Wide 5k]
3. MSK Deviation [Analog
Wide 5k]
P25
NXDN Audio
CWID
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 12) has already adjusted, please skip
Step1 and adjust from Step2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations. If Balance and Maximum
Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 13) have already adjusted, please skip Step2 and adjust from
Step3.
1-100 (No.RA017<Rev.003>)
Necessary adjustment and order
Wide
Wide 4k
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. QT Deviation [Analog
Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DQT Deviation [Analog
Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. LTR Deviation [Analog
Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. DTMF Deviation [Analog
Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. Single TONE Deviation
[Analog Wide 4k]
1. Balance adjust
2. Maximum Deviation
[Analog Wide 4k]
3. MSK Deviation [Analog
Wide 4k]
-
-
-
Narrow
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. QT Deviation [Analog
Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DQT Deviation [Analog
Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. LTR Deviation [Analog
Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. DTMF Deviation [Analog
Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. Single Tone Deviation
[Analog Narrow]
1. Balance adjust
2. Maximum Deviation
[Analog Narrow]
3. MSK Deviation
[Analog Narrow]
-
1. Balance adjust
2. P25 High Deviation
3. P25 High Deviation
(H-CPM)
-
1. Balance adjust
2. High Deviation
[NXDN Narrow]
-
Very Narrow
1. Balance adjust
2. High Deviation
[NXDN Very Narrow]
-
1. Balance adjust
2. High Deviation
[NXDN Very Narrow]
3. CWID Deviation
[NXDN Very Narrow]
-
-
-
-
-
-
-
-

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Nx-5800b