Download Print this page

Kenwood NX-5800 Service Manual page 50

Uhf digital transceiver
Hide thumbs Also See for NX-5800:

Advertisement

4.9
Transmitter Section
Item
Condition
Panel tuning
mode
1.
1) Adj item:
Ramp
[RAMPU]
up
Adjust:[****]
Offset
PTT : ON
Press [
] key to
store the adjust-
ment value.
2.
1) Adj item:
Ramp
[RAMPD]
down
Adjust:[****]
Offset
PTT : ON
Press [
] key to
store the adjust-
ment value.
1-50 (No.RA017<Rev.003>)
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Power
[Ramp Up Offset]
meter
Press [Transmit]
Ammeter
button.
Press [Apply]
button to store the
adjustment value.
Power
meter
Ammeter
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Adjustment
Method
[PC test mode]
[Automatic Adjust-
ment]
1) Press [Tune Rump
Offset] button.
2) Press [Apply All] but-
ton to store the adjust-
ment value after the
automatic adjustment
has finished.
3) Check Ramp UP Off-
set Monitor Value Over
45.
[Manual Adjustment]
1) Set the adjustment
value to "1".
2) Increase the adjust-
ment value slowly while
monitoring the offset
monitor value.
3) Set the adjustment
value when the offset
monitor value exceed
"50".
[PC test mode]
[Automatic Adjust-
ment]
1) If "Automatic Adjust-
ment" is completed in
the item of "Ramp up
Offset", this item is Com-
pleted in addition.
Check Ramp down Off-
set Monitor Value under
50 with PTT ON.
[Manual Adjustment]
1) Set the following val-
ue with reference to the
value that you applied in
the item of "Ramp up
Offset"
2)Write calcurated Val-
ue "Ramp up Offset-70".
3)If the subtraction re-
sult is less than "1", ap-
ply"1".
Specifica-
tions
/Remarks

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Nx-5800b