Download Print this page

Kenwood NX-5800 Service Manual page 51

Uhf digital transceiver
Hide thumbs Also See for NX-5800:

Advertisement

Item
Condition
Panel tuning
mode
3.
1) Adj item:
High
[MAX_H]
Maxi-
Adjust:[****]
mum
2) Adj item:
Power
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
4.
1) Adj item:
Medium
[MAX_M]
Maxi-
Adjust:[****]
mum
2) Adj item:
power
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Adjust:[****]
PTT : ON
Press [
] key to
store the adjust-
ment value.
5.
1) Adj item:
Low
[MAX_L]
Maxi-
Adjust:[****]
mum
2) Adj item:
power
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
PTT : ON
Press [
] key to
store the adjust-
ment value.
6.
1) Adj item:
High
[H_LMT]
Trans-
Adjust:[****]
mit
2) Adj item:
Power
[Low1]→
Limit
[Low5]→
[Center3]→
[High2]→
[High6]
PTT : OFF
Press [
] key to
store the adjust-
ment value.
Measurement
PC test mode
Test-
equip-
ment
1) Adj item:
Power
[High Maximum
meter
Power]
Ammeter
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Press [Transmit]
button.
Press [Apply] but-
ton to store the ad-
justment value.
1) Adj item:
Power
[Medium Maximum
meter
Power]
Ammeter
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Press [Transmit]
button.
Press [Apply] but-
ton to store the ad-
justment value.
1) Adj item:
Power
[Low Maximum
meter
Power]
Ammeter
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Press [Transmit]
button.
Press [Apply] but-
ton to store the ad-
justment value.
1) Adj item:
Power
[High Transmit
meter
Power Limit]
Ammeter
2) Adj item:
[Low1]→
[Low5]→
[Center3]→
[High2]→
[High6]
Press [Apply] but-
ton to store the ad-
justment value.
Unit
Ter-
Unit
Parts
minal
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Panel ANT
Panel [Panel
tuning
mode]
[],
[]
[PC
test
mode]
[←],
[→]
Adjustment
Method
55W
±1W
15A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
55W
±1W
15A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
55W
±1W
15A or less
[PC test
mode]
Press [Apply
All] button to
store the
adjustment
value after all
adjustment
points have
been adjusted.
Write the value as
followings.
256 (Fixed)
(No.RA017<Rev.003>)1-51
Specifica-
tions
/Remarks

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Nx-5800b