Hot Water Heater Installation - Mercury MX 6.2 MPI Installation Manual

Gasoline engine tow sports and inboard models
Hide thumbs Also See for MX 6.2 MPI:
Table of Contents

Advertisement

INSTALLATION MANUAL

Hot Water Heater Installation

IMPORTANT: When connecting a cabin heater or hot water heater:
• Supply hose (from engine to heater) and return hose (from heater to engine)
MUST NOT EXCEED 5/8 in. (16 mm) I.D.
• Make heater connections ONLY at locations shown.
• Refer to manufacturers' instructions for complete installation information and
procedures.
• Do not reposition engine temperature switch.
Avoid a performance loss and/or possible engine damage. Engine coolant must
flow continuously from the engine intake manifold to the engine water circulating
pump. NEVER close-off or block the coolant flow to or from a heater. All heater
installations must be plumbed in series with the supply and return connections.
Avoid engine overheating which could result in engine damage. On models
equipped with Closed Cooling, an air pocket may form in the closed cooling system
if some coolant is lost from the system and the cabin heater or hot water is mounted
higher than the fill cap on the heat exchanger. Heater must be mounted lower than
the fill cap of the heat exchanger on models so equipped.
SUPPLY HOSE CONNECTION
NOTE: Some models may be equipped with additional fittings.
a
Seawater Cooled Models
Page 24 of 77
CAUTION
CAUTION
77816
Closed Cooled Models
INDEX
a
77815
90-864198020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

350 mag mpi horizon350 mag mpi

Table of Contents