Mercury MX 6.2 MPI Installation Manual page 56

Gasoline engine tow sports and inboard models
Hide thumbs Also See for MX 6.2 MPI:
Table of Contents

Advertisement

INSTALLATION MANUAL
BATTERY CABLES
1. Select proper size positive (+) and negative (–) battery cables, using chart. Battery
should be located as close to engine as possible.
IMPORTANT: Terminals must be soldered to cable ends to ensure good electrical
contact. Use electrical grade (resin flux) solder only. DO NOT use acid flux solder, as
it may cause corrosion and a subsequent failure.
Up to 3-1/2 ft. (1.1 m)
3-1/2 - 6 ft. (1.1-1.8 m)
6 - 7-1/2 ft. (1.8-2.3 m)
7-1/2 - 9-1/2 ft. (2.3-2.9 m)
9-1/2 - 12 ft. (2.9-3.7 m)
12 - 15 ft. (3.7-4.6 m)
15 - 19 ft. (4.6-5.8 m)
MULTIPLE EFI ENGINE BATTERY INFORMATION
Batteries: Boats with multi-engine EFI power packages require each engine be connected
to its own battery. This ensures that the engine's Electronic Control Module (ECM) has a
stable voltage source.
Battery Switches: Battery switches should always be positioned so each engine is running
off its own battery. DO NOT operate engines with switches in BOTH or ALL position. In an
emergency, another engine's battery can be used to start an engine with a dead battery.
Battery Isolators: Isolators can be used to charge an auxiliary battery used for powering
accessories in the boat. They should not be used to charge the battery of another engine
in the boat unless the type of isolator is specifically designed for this purpose.
NOTE: Sure Power Industries Inc., Model 32023A meets this design specification.
1. The boat may have two engines connected to a single Model 32023A battery isolator.
2. The Model 32023A battery isolator is connected to two banks of batteries.
3. Each bank contains two batteries with the cranking battery for 1 engine in each bank.
4. The second battery in each bank is connected in parallel to the cranking battery.
5. The Model 32023A battery isolator is designed for this type of use; two battery banks,
two charging sources, 120 amps (maximum alternator output).
6. When the engines are running, either engine's alternator could be charging either bank
of batteries through the Model 32023A battery isolator.
Any other manufacturer's battery isolator that is the same type as the Sure Power Inc.,
Model 32023A could also be used.
Generators: The generator's battery should be considered another engine's battery.
Page 56 of 77
Cable Length
Cable Gauge
2
4 (25 mm
2
2 (35 mm
2
1 (50 mm
2
0 (50 mm
2
00 (70 mm
2
000 (95 mm
2
0000 (120 mm
90-864198020
INDEX
)
)
)
)
)
)
)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

350 mag mpi horizon350 mag mpi

Table of Contents