Ordering Information
Mfr. Part No.
Code
Signet 275X Series Wet-Tap DryLoc pH and ORP Electrodes
pH Electrode
3-2756-WTP
159 001 390 Bulb pH electrode, plastic body, DryLoc connector, use with the 3719 Wet-Tap Assembly only,
3-2756-WTP-1
159 001 384 Bulb pH electrode, plastic body, DryLoc connector, use with the 3719 Wet-Tap Assembly only, 3 KΩ
ORP Electrode
3-2757-WTP
159 001 391 ORP electrode, plastic body, DryLoc connector, use with the 3719 Wet-Tap Assembly only, to use with
Signet 276X Series Diff erential DryLoc pH and ORP Electrodes
pH Electrode
3-2764-1
159 000 943 Flat surface pH diff erential electrode, DryLoc connector, 3 KΩ Balco RTD
3-2764-2
159 000 944 Flat surface pH diff erential electrode, DryLoc connector, Pt1000 RTD for connection to 8900, 9900 and
3-2766-1
159 000 949 Bulb pH diff erential electrode with bulb protection, DryLoc connector, 3 KΩ Balco RTD
3-2766-2
159 000 950 Bulb pH diff erential electrode with bulb protection, DryLoc connector, Pt1000 RTD for connection to
ORP Electrode
3-2765-1
159 000 946 Flat surface ORP diff erential electrode, DryLoc connector, 10 KΩ ID resistor for connection to 8900,
3-2767-1
159 000 952 Bulb ORP diff erential electrode with bulb protection, DryLoc connector, 10 KΩ ID resistor for connection
Signet 277X Series Threaded DryLoc pH and ORP Electrodes
pH Electrode
3-2774
159 000 955 Flat surface pH electrode, DryLoc connector, 3 KΩ Balco RTD
3-2774-1
159 000 956 Flat surface pH electrode, DryLoc connector, Pt1000 RTD for connection to 8900, 9900 and 9950
3-2774-HT
159 001 796
3-2774-HT-C
159 001 795
3-2774-HT-ISO
159 001 794
3-2776
159 000 959 Bulb pH electrode with bulb protection, DryLoc connector, 3 KΩ Balco RTD
3-2776-1
159 000 960 Bulb pH electrode with bulb protection, DryLoc connector, Pt1000 RTD for connection to 8900, 9900 and
Signet 277X Series Threaded DryLoc pH and ORP Electrodes
ORP Electrodes
3-2775
159 000 957
3-2777
159 000 961 Bulb ORP electrode with bulb protection, DryLoc connector, 10 KΩ ID resistor for connection to the 8900,
Description
Pt1000 RTD for connection to the 8900, 9900 and 9950 instruments when used with the 2751 Smart
Sensor Electronics
Balco RTD
2751 Smart Sensor Electronics or 2760 Preamplifi er
9950 instruments when used with the 2751 Smart Sensor Electronics
8900, 9900 and 9950 instruments when used with the 2751 Smart Sensor Electronics
9900 or 9950 when used with the 2751 Smart Sensor Electronics
to 8900, 9900 or 9950 when used with the 2751 Smart Sensor Electronics
instruments when used with the 2751 Smart Sensor Electronics
Flat surface pH electrode, DryLoc connector, 3KΩ Balco RTD, High Temperature (110 °C, 230 °F)
in-line install only
.
Flat surface pH electrode, DryLoc connector, BNC connector, 3KΩ Balco RTD, NPT, High Temperature
(110 °C, 230 °F), NPT, 15 ft cable, no memory chip, for submersible installations, can only be connected
to the 2751 or 2760 sensor electronics if used with the 3-2722 BNC adapter.
Flat surface pH electrode, DryLoc connector, 3 KΩ Balco RTD, High Temperature (110 °C, 230 °F),
3/4" ISO, 3KΩ Balco RTD, in-line install only.
9950 instruments when used with the 2751 Smart Sensor Electronics
Flat surface ORP electrode, DryLoc connector, 10 KΩ ID resistor for connection to the 8900, 9900 or 9950
when used with the 2751 Smart Sensor Electronics
9900 or 9950 when used with the 2751 Smart Sensor Electronics
Signet 275X, 276X, 2777X Series pH and ORP Electrodes
,
11
Need help?
Do you have a question about the Signet 276 Differential Series and is the answer not in the manual?