Problem
Machine does not start
Pot separation unit fails
2nd hand pots are not
separated.
Amount of soil provided is
not enough
No soil provided

7.8 Adjust substrate conveyor to larger stroke

At Plus Extra is generally worked with fairly large pots. As a result, it may be that all pots
are not filled quickly enough with substrate. It is possible to increase (on the plus) the
stroke of the substrate in-feed conveyor.
Procedure:
1. Remove protective cover (A).
a. Loosen the M8 bolts three turns.; The protective cover is removable.
2. Loosen with two wrenches (No. 19), bolt and nut (B).
3. Now, rod (A) can be adjusted.
a. Rod (A) can be adjusted onto two holes:
i. With hole (1) the stroke of substrate
ii. With hole (2) the stroke of substrate
Version 2015-1
Possible cause
Door safety switch is open
Emergency stop button is not
pulled
Emergency stop button not reset
Breaker tripped in main cabinet
A second machine in line is not
ready.
Cylinder is too slow for subsequent
movement making machine
completion steps are not
completed. Valve is possible
contaminated.
Pots too tight together.
Soilslide is set too low.
Soilslide is set too low and a tunnel
is build up above the soil conveyor.
belt slipping
Substrate conveyor is delivering
not enough substrate.
Belt slipping.
Sensors dirty.
Outflow mouth clogged.
Elevator is stuck
conveyor is the smallest.
conveyor is the biggest.
User Manual Javo Plus en Plus Extra Potmachine
Action / Solution
Close door and reset the safety circuit by pressing
the reset button
Pull Emergency Stop button and reset the safety
circuit by pressing the reset button
Reset the safety circuit by pressing the reset button
See why circuit breaker has tripped. Remove
obstacles to conveyors. Switch on the machine
after solving the problem.
Clear second machine in line.
Replace the relevant valve.
Do not use 2nd hand pots.
Set the soil slide higher.
Set the soil slide higher.
Check conveyor tension
Follow procedure section 7.8.
Check tension.
Clean sensors . Adjust the sensitivity.
Clean.
Move elevator back and forwards and decrease the
soil supply.