Disassembly Procedures
!
W AR NIN G

Door Disassembly

1. Disconnect power from microwave and remove oven
door, (see "Door Removal" procedure).
2. Pry away choke cover, by placing a tool in the upper
right corner of the door and gently prying outward on
the choke cover. Continue to work around the door
casing until choke cover is completely loose.
!
CAUTION
To avoid property damage, care must be taken when
prying choke cover from oven door.
3. Slide latch assembly upward and left to release tabs
from door frame. Once latch assembly is loose the
spring may be disconnected from the door frame.
4. Remove screws securing door frame assembly to
door panel.
5. Remove door frame assembly by releasing tabs
around entire door panel.
6. Remove door handle by removing screws securing
handle to door panel.
NOTE: The door handle can only be re-installed by
guiding the top and bottom insertion points into
the correct receiving slots. It is impossible to re-
install the door handle "upside-down."
7. Remove door glass by releasing tab securing door
glass baffle. Remove baffle, then slide door glass to
the right slightly, then push the door glass upward to
release the glass from the track.
8. Reassemble in reverse order.
Baffle
Glass
Door Panel
!
CAUTION
A microwave leakage test must be performed anytime
a door assembly is removed, replaced, disassembled,
or adjusted for any reason.
18
Choke
Cover
Door Frame
Assembly
Latch
Spring
16026440
To avoid the risk of electrical shock, personal injury or
death; disconnect power to microwave and discharge
capacitors before following any disassembly procedure.

Control Panel

The control panel is made up of several components,
such as p.c. board and touch panel.

Control Panel Removal

1. Disconnect power from microwave.
2. Remove grill assembly, see "Grill Assembly"
procedure.
3. Remove screw securing touch panel to chassis. Lift
control panel up and out to release bottom tab
connections.
4. Disconnect connectors from control panel.
5. Place control panel on a flat surface.
6. Reassemble in reverse order.

P.C. Board

The p.c. board is located at the top on back of the
control panel.

P. C. Board Removal

1. Disconnect power from microwave.
2. Discharge high voltage capacitor, see "High Voltage
Capacitor" procedure.
3. Remove control panel, see "Control Panel Removal"
procedure.
4. Remove screws securing p.c. board to the control
panel.
5. Lift p.c. board up and out to remove from control
panel.
6. Reassemble in reverse order.
NOTE: When reconnecting the Plexible Printed Circit
(FPC) connector, ensure the connector holes
are properly engaged with the hooks on the
plastic fastener.
©2005 Maytag Services