Switching On The Refrigerator (Rml9331/Rml9335) - Dometic 9 Series Operating Manual

Absorber refrigerator
Hide thumbs Also See for 9 Series:
Table of Contents

Advertisement

RML93xx
➤ Press in the battery igniter as well and hold it down (B).
✓ The burner is ignited automatically. The needle of the pilot light moves to the
green zone once the burner has ignited (C).
➤ Press and hold down the temperature regulator for another 15 seconds.
7.3

Switching on the refrigerator (RML9331/RML9335)

➤ Press and hold the
✓ The refrigerator starts with the last type of power selected.
Operating with AC power supply
➤ Press the
button.
Operating with DC power supply
I
NOTE
Only select operation with DC power supply (battery mode) if the vehi-
cle engine is running and providing sufficient voltage to the light system,
or if you are using a battery monitor.
➤ Press the
button.
Gas operation
!
WARNING! Fire hazard!
Never operate the refrigerator with gas at petrol stations.
I
NOTE
When operating with LPG, the burner must be cleaned frequently
(two or three times a year).
➤ Press the
button.
✓ The burner is ignited automatically.
EN
button for two seconds.
Using the refrigerator
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rml9335Rml9331Rml9330

Table of Contents