5.3

Setting and menu operation

Table 5-2 shows an overview of the available measuring points and the associated display formats. Table 5-3 summarises the
views of the calculated parameters.
Measuring
point
T
K
T
R
T
S
T
V
V
Table 5-2 Overview of measuring points
Parameter
TK max
TK min
V max
PS
HP (15h)
W (15h)
W
P
DT
P1
Stage min
Stage on
Table 5-3 Maximum values and calculated values
FA ROTEX Solaris RPS3 P2 - 06/2012
Name
Display
Solar panel temperature
-30 to 250 °C
Return flow temperature
0 to 100 °C
Storage tank temperature
0 to 100 °C
Flow temperature
0 to 100 °C
0.0 to 12.0 l/min
0.0 to 20.0 l/min
Flow
0.0 to 40.0 l/min
0.0 to 100.0 l/min
Name
Maximum measured solar
-30 to 250 °C
panel temperature
Minimum measured solar panel
-30 to 250 °C
temperature
0.0 to 12.0 l/min
0.0 to 20.0 l/min
Maximum flow
0.0 to 40.0 l/min
0.0 to 100.0 l/min
Peak output
0.0 to 99.9 kW
Daily peak output
0.0 to 99.9 kW
Daily heat yield
0.0 to 999.9 kW
0.0 to 9999.9 kW
Total heat yield
or 10.000 to
99.999 kW
Instantaneous output
0.0 to 99.9 kW
Nominal spread
1 to 15 K
Current output stage P1
0 to 100 %
Lowest released output
0 to 10;
stage P1
0 to 100 %
Runtime of tank circulation
0 to 99999h
pump P1
Measuring range
Resolution
1 K
1 K
1 K
1 K
0.1 l/min
Value range
Resolution
1 K
1 K
0.1 l/min
0.1 kW
0.1 kW
0.1 kWh
0.1 kWh
0.0001 MWh
0.1 kW
1 K
1 %
1; 1 %
1 h
5
x
Operation
Sensor
PT 1000 temperature sensor
PTC temperature sensor
PTC temperature sensor
FlowSensor with voltage output 0.5 to 3.5 V
FlowSensor 12 with voltage output
0.5 to 3.5 V
FlowSensor 20 with voltage output
0.5 to 3.5 V
FlowSensor 40 with voltage output
0.5 to 3.5 V
FlowSensor 100 with voltage output
0.5 to 3.5 V
Remark
none
none
Maximum flow that was reached during filling
with FlowSensor 12
Maximum flow that was reached during filling
with FlowSensor 20
Maximum flow that was reached during filling
with FlowSensor 40
Maximum flow that was reached during filling
with FlowSensor 100
Maximum value from 5 min output average
Maximum value of peak output in the last 15 h
Heat yield from instantaneous output in the
last 15 h
Total solar heat yield calculated from
instantaneous output
Average value of the last minute
Nominal temperature difference T
modulation operation (calculated)
none
Only available with technician access
(see image 5-9)
Only available with technician access
(see image 5-9)
–T
at
V
R
33