Troubleshooting

Fault-type operational events:
Storage tank temperature "T
– The pumps are switched off, the system runs empty. On the Solaris R3P control system the T
shows the measured tank temperature. As soon as the storage temperature falls more than 2 K, normal system operation is
resumed.
Temperature in the solar panels is higher than the cut-in protection temperature "T
– The pumps are switched off. In the Solaris R3P control system the T
falls by more than 2 K, normal system operation is enabled automatically.
Faults
In the Solaris R3P control system the T
the storage temperature "T
• Install the sensor correctly or replace it; normal system operation will be resumed.
The fault signal "W" is shown in the left column of the Solaris R3P control system display.
During the start procedure after expiry of time PsE and time UB the minimum flow corresponding to start phase "V1" table 5-1
was not reached at the FlowSensor. The system is temporarily blocked for 2 h and then automatically attempts to start.
FA ROTEX Solaris RPS3 P2 - 06/2012
Sensor
Cause of the
fault
Interruption
Short circuit
Interruption
Short circuit
Interruption
Short circuit
Voltage drop
Voltage drop
Sensor fault table
" in the hot water storage tank reaches the value set in parameter "T
S
WARNING!
Live parts can cause an electric shock on contact and cause life-threatening burns and injuries.
• Electrical installations must always be carried out by qualified electrical technicians in conformity with the
relevant electrical guidelines and the regulations of the electric utilities company to prevent hazards from
damaged electric wiring.
• Faults on conducting parts of the Solaris RPS3 P2 may only be carried out by heating specialists who have
been authorised and accredited by the electrical utility company (EVU).
• Before commencing repair work, disconnect the Solaris RPS3 P2 and all system parts from the power
supply (fuse, switch off main switch) and prevent them from being switched on accidentally again.
• Comply with the relevant safety at work regulations.
CAUTION!
Danger of burning due to hot surfaces
• Let the burner cool down for a reasonably long time before maintenance and service work.
• Wear protective gloves.
". The pumps are switched off. The cause is a defective or incorrectly connected sensor.
S
Status
Display
(flashes)
K
uuuu
––––
R
uuuu
––––
S
uuuu
––––
V
––––
D
––––
light flashes. Return temperature "T
R
6
x
Faults and malfunctions
Lamp
Consequence
(flashing)
TK
TK
TR
Permanent switch-off of P1 and P2
TR
TS
TS
without lamp
Operation without FlowSensor
without lamp
max":
S
light flashes, the display
S
zul":
K
light flashes. If the set switch-on inhibit temperature
K
" is greater than 40 °C and is 10 K higher than
R
43